IJ SERIES ION SELECTIVE ELECTRODES
- Home
- / Electrode
- / Intermediate Junction Electrodes (IJ Series)
- / IJ Series Ion Selective Electrodes
- IJ-Ag2S INTERMEDIATE JUNCTION POLYPROPYLENE/PEEK BODY REFILLABLE SILVER/SULPHIDE ION SELECTIVE ELECTRODE
Body: | Polypropylene/PEEK |
Temp Range: | 0 – 60°C |
Parameter: | S2-, Ag+ |
PH Range: | 2 – 7 (silver) > 9 (sulphide) |
Reference: | Double junction Ag/AgCl (intermediate junction) |
Measuring Range: | S2-: 0.003 to 32100 ppm Ag+: 0.01 to 107900 ppm |
Interfering Ions: | Hg2+ |
- IJ-Br INTERMEDIATE JUNCTION POLYPROPYLENE/PEEK BODY REFILLABLE BROMIDE COMBINATION ION SELECTIVE ELECTRODE
Body: | Polypropylene/PEEK |
Parameter: | Br – |
Reference: | Double Junction Ag/AgCl/Sat KCl Gel with replaceable electrolyte |
Temp Range: | 0°C – 60°C |
PH Range: | 2 – 12 |
Measuring Range: | 0.8 – 80000 ppm |
Interfering Ions: | I-, S2-, CN-, SCN- |
Applications: | Suitable for the direct determination of Bromide ions, as well as an indicator in argentometric titration. |
Cable Length: | 1m. Standard (Max. 20m) |
Connector: | BNC Standard |
- IJ-CI INTERMEDIATE JUNCTION POLYPROPYLENE/PEEK BODY REFILLABLE CHLORIDE COMBINATION ION SELECTIVE ELECTRODE
Body: | Polypropylene, PEEK |
Parameter: | Cl-, Ag+ |
Reference: | Double Junction Ag/AgCl/Sat KCl Gel with replaceable electrolyte |
Temp Range: | 0°C – 60°C |
PH Range: | 2 – 12 |
Measuring Range: | 1.8 – 35000 ppm |
Interfering Ions: | I-, CN-, Br-, SCN- |
Applications: | Suitable for both the direct determination of Chloride and Silver, as well as an indicator in argentometric titration./td> |
Cable Length: | 1m. Standard (Max. 20m) |
Connector: | BNC Standard |
- IJ–CN INTERMEDIATE JUNCTION POLYPROPYLENE/PEEK BODY REFILLABLE CYANIDE COMBINATION ION SELECTIVE ELECTRODE
Body: | Polypropylene, PEEK |
Parameter: | CN- |
Reference: | Double Junction Ag/AgCl/Sat KCl Gel with replaceable electrolyte |
Temp Range: | 0°C – 60°C |
PH Range: | 9 – 14 |
Measuring Range: | 0.05 – 25 ppm |
Interfering Ions: | I-, Br-, S2- |
Applications: | Suitable for the direct determination of Cyanide ions in alkaline conditions. If the concentration of CN- > 10ppm, dilution before measurement is recommended. |
Cable Length: | 1m. Standard (Max. 20m) |
Connector: | BNC Standard |
- IJ-F INTERMEDIATE JUNCTION POLYPROPYLENE/PEEK BODY REFILLABLE FLUORIDE COMBINATION ION SELECTIVE ELECTRODE
Body: | Polypropylene, PMMA |
Parameter: | F- |
Reference: | Double Junction Ag/AgCl/Sat KCl Gel with replaceable electrolyte |
Temp Range: | 0°C – 60°C |
PH Range: | 5-7 |
Measuring Range: | 0.2 – 19000 ppm |
Interfering Ions: | OH- |
Applications: | Suitable for the direct determination of Fluoride ions, as well as an indicator in Lanthanum ion titrations. |
Cable Length: | 1m. Standard (Max. 20m) |
Connector: | BNC Standard |
- IJ-I INTERMEDIATE JUNCTION POLYPROPYLENE/PEEK BODY REFILLABLE IODIDE COMBINATION ION SELECTIVE ELECTRODE
Body: | Polypropylene, PEEK |
Parameter: | I- |
Reference: | Double Junction Ag/AgCl/Sat KCl Gel with replaceable electrolyte |
Temp Range: | 0°C – 60°C |
PH Range: | 2 – 12 |
Measuring Range: | 0.13 – 130000 ppm |
Interfering Ions: | CN-, Hg2+, Br-, SCN- |
Applications: | Suitable for the direct determination of Iodide ions, as well as an indicator in argentometric titration. |
Cable Length: | 1m. Standard (Max. 20m) |
Connector: | BNC Standard |