The IJ14 – Intermediate Junction  Ag/AgCl reference electrode suited for use with a wide variety of indicator electrodes such as PH, ISE and metal half-cells. The double junction design allows the user to select electrolytes suitable for use with the majority of ion selective electrode half-cells. Suitable electrolytes commonly used include KCl, KNO3, NH4NO3, and ethanolicLiCl. The IJ14 can also be used to monitor potentials of various processes such as corrosion.
Body: Polypropylene
Temp Range: 0 – 60°C
Reference: Double Junction Ag/AgCl/Sat KCl Gel
Cable Length: 1m. Standard (Max. 20m)
Connector: 4mm Banana Standard
Dimension: 12mm x 120mm
Body: Polypropylene
Temp Range: 0 – 60°C
ORP Range: ±2000mV
ORP Sensor: Gold
Reference: Double Junction Ag/AgCl/Sat KCl Gel
Cable Length: 1m. Standard (Max. 20m)
Connector: BNC Standard
Notes: General purpose ORP electrode
Dimensions: 12mm x 120mm
Body: Polypropylene
Temp Range: 0 – 60°C
ORP Range: ±2000mV
ORP Sensor: Platinum
Reference: Double Junction Ag/AgCl/Sat KCl Gel
Cable Length: 1m. Standard (Max. 20m)
Connector: BNC Standard
Notes: General purpose ORP electrode
Dimensions: 12mm x 120mm
Body: Kynar
Temp Range: 0 – 100°C
ORP Range: ±2000mV
ORP Sensor: Platinum
Reference: Double Junction Ag/AgCl/Sat KCl Gel
Cable Length: 1m. Standard (Max. 20m)
Connector: BNC Standard
Notes: General purpose high Temp ORP electrode
Dimensions: 12mm x 120mm
Body: Polypropylene
Temp Range: 0 -60°C
PH Range: 0 -14 PH
PH Sensor: A / C Glass Bullet
Reference: Double Junction Ag/AgCl/Sat KCl Gel
Cable Length: 1m. Standard (20m Max)
Dimensions: 12mm x 120mm
Connector: BNC Standard
Body: Polypropylene
Temp Range: 0 -60°C
PH Range: 0 -14 PH
PH Sensor: A / C Glass Spear
Reference: Double Junction Ag/AgCl/Sat KCl Gel
Cable Length: 1m. Standard (20m Max)
Dimensions: 12mm x 120mm
Connector: BNC Standard
Body: Polypropylene
Temp Range: 0 -60°C
PH Range: 0 -12 PH
PH Sensor: A / C Glass Spear
Reference: Double Junction Ag/AgCl/Sat KCl Gel
Cable Length: 1m. Standard (20m Max)
Dimensions: 12mm x 120mm
Connector: BNC Standard
Body: KYNAR / PVDF
Temp Range: 0 -60°C
PH Range: 0 -14 PH
PH Sensor: A / C Glass Spear
Reference: Double Junction Ag/AgCl/Sat KCl Gel
Cable Length: 1m. Standard (20m Max)
Dimensions: 12mm x 120mm
Connector: BNC Standard
Body: Polypropylene
Range: ±2000Mv
Range: 0 -14 PH
PH Sensor: Silver
Reference: Double Junction Ag/AgCl/Sat KCl Gel
Reference: Double Junction Ag/AgCl/User Selectable Electrolyte
Cable Length: 1m. Standard (Max. 20m)
Connector: BNC Standard
Note: For argentimetric titration using silver nitrate or similar