- IJ14 INTERMEDIATE JUNCTION REFERENCE ELECTRODE
The IJ14 – Intermediate Junction Ag/AgCl reference electrode suited for use with a wide variety of indicator electrodes such as PH, ISE and metal half-cells. The double junction design allows the user to select electrolytes suitable for use with the majority of ion selective electrode half-cells. Suitable electrolytes commonly used include KCl, KNO3, NH4NO3, and ethanolicLiCl. The IJ14 can also be used to monitor potentials of various processes such as corrosion.
Body: | Polypropylene |
Temp Range: | 0 – 60°C |
Reference: | Double Junction Ag/AgCl/Sat KCl Gel |
Cable Length: | 1m. Standard (Max. 20m) |
Connector: | 4mm Banana Standard |
Dimension: | 12mm x 120mm |
- IJAU INTERMEDIATE JUNCTION POLYPROPYLENE BODY REFILLABLE GOLD SENSOR ORP ELECTRODE
Body: | Polypropylene |
Temp Range: | 0 – 60°C |
ORP Range: | ±2000mV |
ORP Sensor: | Gold |
Reference: | Double Junction Ag/AgCl/Sat KCl Gel |
Cable Length: | 1m. Standard (Max. 20m) |
Connector: | BNC Standard |
Notes: | General purpose ORP electrode |
Dimensions: | 12mm x 120mm |
- IJ64 INTERMEDIATE JUNCTION POLYPROPYLENE BODY REFILLABLE PLATINUM SENSOR ORP ELECTRODE
Body: | Polypropylene |
Temp Range: | 0 – 60°C |
ORP Range: | ±2000mV |
ORP Sensor: | Platinum |
Reference: | Double Junction Ag/AgCl/Sat KCl Gel |
Cable Length: | 1m. Standard (Max. 20m) |
Connector: | BNC Standard |
Notes: | General purpose ORP electrode |
Dimensions: | 12mm x 120mm |
- IJ64HT INTERMEDIATE JUNCTION KYNAR BODY REFILLABLE PLATINUM SENSOR ORP ELECTRODE
Body: | Kynar |
Temp Range: | 0 – 100°C |
ORP Range: | ±2000mV |
ORP Sensor: | Platinum |
Reference: | Double Junction Ag/AgCl/Sat KCl Gel |
Cable Length: | 1m. Standard (Max. 20m) |
Connector: | BNC Standard |
Notes: | General purpose high Temp ORP electrode |
Dimensions: | 12mm x 120mm |
- IJ40 INTERMEDIATE JUNCTION POLYPROPYLENE BODY REFILLABLE BULLET SENSOR PH ELECTRODE
Body: | Polypropylene |
Temp Range: | 0 -60°C |
PH Range: | 0 -14 PH |
PH Sensor: | A / C Glass Bullet |
Reference: | Double Junction Ag/AgCl/Sat KCl Gel |
Cable Length: | 1m. Standard (20m Max) |
Dimensions: | 12mm x 120mm |
Connector: | BNC Standard |
- IJ44 INTERMEDIATE JUNCTION POLYPROPYLENE BODY REFILLABLE SPEAR SENSOR PH ELECTRODE
Body: | Polypropylene |
Temp Range: | 0 -60°C |
PH Range: | 0 -14 PH |
PH Sensor: | A / C Glass Spear |
Reference: | Double Junction Ag/AgCl/Sat KCl Gel |
Cable Length: | 1m. Standard (20m Max) |
Dimensions: | 12mm x 120mm |
Connector: | BNC Standard |
- IJ46 INTERMEDIATE JUNCTION POLYPROPYLENE BODY REFILLABLE FLAT SENSOR PH ELECTRODE
Body: | Polypropylene |
Temp Range: | 0 -60°C |
PH Range: | 0 -12 PH |
PH Sensor: | A / C Glass Spear |
Reference: | Double Junction Ag/AgCl/Sat KCl Gel |
Cable Length: | 1m. Standard (20m Max) |
Dimensions: | 12mm x 120mm |
Connector: | BNC Standard |
- IJ44HT INTERMEDIATE JUNCTION KYNAR BODY REFILLABLE SPEAR SENSOR PH ELECTRODE
Body: | KYNAR / PVDF |
Temp Range: | 0 -60°C |
PH Range: | 0 -14 PH |
PH Sensor: | A / C Glass Spear |
Reference: | Double Junction Ag/AgCl/Sat KCl Gel |
Cable Length: | 1m. Standard (20m Max) |
Dimensions: | 12mm x 120mm |
Connector: | BNC Standard |
- IJ-Ag INTERMEDIATE JUNCTION POLYPROPYLENE BODY REFILLABLE SILVER BILLET SENSOR ELECTRODE FOR ARGENTIMETRIC TITRATION
Body: | Polypropylene |
Range: | ±2000Mv |
Range: | 0 -14 PH |
PH Sensor: | Silver |
Reference: | Double Junction Ag/AgCl/Sat KCl Gel |
Reference: | Double Junction Ag/AgCl/User Selectable Electrolyte |
Cable Length: | 1m. Standard (Max. 20m) |
Connector: | BNC Standard |
Note: | For argentimetric titration using silver nitrate or similar |