IJ SERIES PH and ORP ELECTRODES

IONODE
 
 
     
»  IJ14 Intermediate Junction Reference Electrode »  IJ40A Intermediate Junction pH Electrode
»  IJ40C Intermediate Junction pH Electrode »  IJ44A Intermediate Junction pH Electrode,
pH 0 – 12
»  IJ44C Intermediate Junction pH Electrode,
pH 0 – 14
»  IJ44C-HT Enhanced Series Intermediate Junction pH Electrode, pH 0 – 14
»  IJ64 Intermediate Junction ORP Electrodes »  IJ64 HT Intermediate Junction ORP Electrode
»  IJ-Ag Intermediate Junction Silver Billet Electrode »  Intermediate Junction Gold ORP Electrode (IJ-Au)


IJ14 Intermediate Junction Reference Electrode
Body: Polypropylene
Temp Range: 0 - 60°C
Reference: Double Junction Ag/AgCl/Sat KCl Gel
Cable Length: 1m. Standard (Max. 20m)
Connector: 4mm Banana Standard
Dimension: 12mm x 120mm
IJ40A Intermediate Junction pH Electrode
Body: Polypropylene
Temp Range: 0 -60°C
pH Range: 0 -12 pH
pH Sensor: A Glass Bullet
Reference: Double Junction Ag/AgCl/Sat KCl Gel
Slope:  >98%
IJ40C Intermediate Junction pH Electrode
Body: Polypropylene
Temp Range: 0 -60°C
pH Range: 0 -14 pH
pH Sensor:C C Glass Bullet
Reference: Double Junction Ag/AgCl/Sat KCl Gel
Slope:  >98%
IJ44A Intermediate Junction pH Electrode, pH 0 – 12
Body: Polypropylene
Temp Range: 0 -60°C
pH Range: 0 -12 pH
pH Sensor: A Glass Spear
Reference: Double Junction Ag/AgCl/Sat KCl Gel
Slope: >98%
Zero pH Value: 7.0 ± 0.5
Cable Length: 1m. Standard (20m Max)
Dimensions: 12mm x 120mm
Connector: BNC Standard
IJ44C Intermediate Junction pH Electrode, pH 0 – 14
Body: Polypropylene
Temp Range: 0 - 60oC
pH Sensor: C Glass Spear
pH Range: 0 - 14 pH
Reference: Double Junction Ag/AgCl/Sat KCl Gel
Slope: >98%
Zero pH: 7.0 ± 0.5
Cable Length: 1m. Standard (Max. 20m)
Connector: BNC Standard
Dimensions:  12mm x 120mm
IJ44C-HT Enhanced Series Intermediate Junction pH Electrode, pH 0 – 14
Body: Kynar
Temp Range: 0 -100°C
pH Range: 0 -14 Ph
pH Sensor: A Glass Spear
Reference: Double Junction Ag/AgCl/Sat KCl Gel with replaceable electrolyte
Slope: >98%
Zero pH Value: 7.0 ± 0.5
Cable Length: 1.0m Standard (20m Max)
IJ64 Intermediate Junction ORP Electrodes
Body: Polypropylene
Temp Range: 0 - 60°C
ORP Range: ±2000mV
ORP Sensor: Platinum
Reference: Double Junction Ag/AgCl/Sat KCl Gel
Cable Length: 1m. Standard (Max. 20m)
Connector:  BNC Standard
Notes: General purpose ORP electrode
Dimensions: 12mm x 120mm
IJ64 HT Intermediate Junction ORP Electrode
Body: Kynar
Temp Range: 0 - 100°C
ORP Range: ±2000mV
ORP Sensor: Platinum
Reference: Double Junction Ag/AgCl/Sat KCl Gel
Cable Length: 1m. Standard (Max. 20m)
Connector:  BNC Standard
Notes: General purpose high Temp ORP electrode
Dimensions: 12mm x 120mm
IJ-Ag Intermediate Junction Silver Billet Electrode
Body: Polypropylene
Temp Range: 0 - 60°C
Range: ±2000mV
Sensor: Silver
Reference: Double Junction Ag/AgCl/User Selectable Electrolyte
Cable Length: 1m. Standard (Max. 20m)
Connector: BNC Standard
Note: For argentimetric titration using silver nitrate or similar
Intermediate Junction Gold ORP Electrode ( IJ-Au)
Body: Polypropylene
Temp Range: 0 - 60°C
Range: ±2000mV
Sensor: Gold
Reference: Double Junction Ag/AgCl/Sat KCl gel
Cable Length: 1m. Standard (Max. 20m)
Connector: BNC Standard
Note: Suitable for ORP measurements in reducing environments
 
 
 
 